NMHCs_GC_online_Medusa_JFJ

operational
🔬 gas chromatograph, online

📝 Notes

* Measurement height above ground: Do you mean 'inlet' height? 'Measurement height' does not make much sense, that would be the height of the instrument? * Measurement height above building: The 'inlet height' is 10 m below the building. This height is only true for data starting July 2020. * Sample air flow: Please note that the 80 m sampling line is continuously flushed at 5 L/min using a dual-membrane GAST pump. Upstream of that pump, there is branch of to the KNF sampling pump, which periodically samples at 100 ml/min

💨 Sample from 2008-01-01
Pump
Pump model [Referenz-ID: 900]
Kind of pump Membrane
Pump manufacturer [Referenz-ID: 576]
Air flow 100.0 mL/min
Sample air flow select Vacuum sampling
🔧 Inlet System from 2008-01-01
Line heating 10.0 degC
Residence time 62.0 s
Lower mesh size 0.5 µm
Upper mesh size 0.5 µm
Inlet tube material Other
Filter inlet material Stainless steel
Distance from nox inlet 50.0 m
Inlet line heating bool
Distance from ozone inlet 50.0 m
Inlet tube material if other not specified
Measurement height above ground 2.0 m
Measurement height above building -10.0 m
⚗️ GC System from 2008-01-01
First column
Length 60.0 m
Material GS-GASPRO
Film thickness 0.05 µm
Inner diameter 320.0 µm
Second column
Length 25.0 m
Material CP-PoraBOND Q
Film thickness 0.45 µm
Inner diameter 320.0 µm
Instrument model [Referenz-ID: 912]
Pre column select box
Instrument manufacturer [Referenz-ID: 547]
Instrument serial number CN10641022
Second column select box
📡 Detection from 2008-01-01
Select Mass spectrometry
Mass spectrometry
Type Quadrupole
Tune freq Monthly
Mass spectrometry model [Referenz-ID: 913]
Mass spectrometry manufacturer [Referenz-ID: 547]
Mass spectrometry serial number US62734337
🌬️ Air Sampling from 2008-01-01
Sampling volume 2000.0 L
Sampling duration 20.0 min
Sampling system model [Referenz-ID: 887]
Air sampling technique Concentrating on adsorbents
Concentrating on adsorbents
Adsorption material Hayesep
Adsorption temperature -160.0 degC
Desorption temperature 100.0 degC
Sampling system manufacturer [Referenz-ID: 886]
Sampling system serial number Medusa-12
📐 Calibration from 2008-01-01
Blank substraction Applied
Zero gas generation Other
Calibration frequency 2.0 hours
Number of repetitions 1.0
Zero gas blank frequency 1.0 weeks
Linearity check frequency 12.0 months
Zero gas generation if other Alltec

Calibration Certificates (1)

Name: NPL_NMHCs_2014_JFJ Supplier: NPL Cylinder: D99 4220 Valid: 2014-03-03 → 2026-03-02
🧪 Air Treatment from 2008-01-01
Bool other
Co2 removal None
Water removal Nafion
Oxidant removal None
Particle removal Stainless steel screen
📤 Data Submission
Databases
Database Submission
ACTRIS 1.0 years
✅ Data QA/QC
Bool voc
Bool other
Bool ratios
Bool calibrations
📋 Measurement QA/QC
Checklist 1.0 weeks
Instrument log book Electronic
🧬 Compounds from 2008-01-01
#NameFormulaID
1 2-methylbutane 166
2 2-methyl-propane 164
3 benzene 225
4 ethane 252
5 propane 361
6 toluene 380
👤 Operators
OperatorLevel
User #21 scientist